What are you looking for?
420 hits in Complete website
Filters
Subjects
Year
Selected filters
-
Equinor – Hammerfest LNG – alarm management system in control roomPublished:Equinor – Hammerfest LNG – alarm management system in control room The Petroleum Safety Authority Norway (PSA) has carried out an audit of Equinor and its management of responsibilities for, competence
- Audit report
- Technical safety
- Working environment
- Equinor
- Melkøya
-
Equinor has complied with Havtil’s order regarding Hammerfest LNGPublished:Equinor has complied with Havtil’s order regarding Hammerfest LNG Equinor has complied with Havtil’s order regarding Hammerfest LNG On 20 June 2025, the Norwegian Ocean Industry Authority (Havtil) issued
- News
- Working environment
- Process safety
- Risk management
-
Equinor – Hammerfest LNG – materials handling, cranes and lifting, and maintenancePublished:Equinor – Hammerfest LNG – materials handling, cranes and lifting, and maintenance Equinor – Hammerfest LNG – materials handling, cranes and lifting, and maintenance The Petroleum Safety Authority Norway
- Audit report
- Emergency preparedness
- Risk management
- Equinor
- Melkøya
-
Statoil - Hammerfest LNG - Cranes lifting and Working environmentPublished:Statoil - Hammerfest LNG - Cranes lifting and Working environment Statoil - Hammerfest LNG - Cranes lifting and Working environment From 7 to 9 March 2017, we carried an audit of the Hammerfest LNG plant.
- Audit report
- Working environment
- Handling, cranes and lifting
- Maintenance management
- Statoil
- Melkøya
-
Statoil - Hammerfest LNG - Investigation of hydrocarbon leakPublished:Statoil - Hammerfest LNG - Investigation of hydrocarbon leak The hydrocarbon leak at the Hammerfest LNG facility in northern Norway on 5 January 2014 had a big accident potential and could have led to
- Investigation report
- Emergency preparedness
- Process safety
- Melkøya
- Statoil
-
Equinor – Hammerfest LNG – working environment risk and employee participationPublished:Equinor – Hammerfest LNG – working environment risk and employee participation The Petroleum Safety Authority Norway (PSA) has carried out an audit of Equinor and their management of working environment
- Audit report
- Working environment
- Equinor
- Melkøya
-
§ 30 Passive fire protectionPassive fire protection 30 Where passive fire protection is used, this shall be designed such that it provides relevant structures and equipment with sufficient fire resistance as regards load capacity
- Paragraph
- Technical and operational regulations
-
§ 30 Fire divisionsFire divisions 30 Main areas and fire areas on facilities shall be separated by fire divisions that can withstand the design loads for fire and explosion. If the fire divisions may be exposed to hydrocarbon
- Paragraph
- The facilities regulations
-
Re § 30 Fire divisionsFire divisions 30 For fire divisions in living quarters, see Section 31. For determination of fire and explosion loads as mentioned in the first and second subsections, see Section 11. Worst credible
- Guideline
- The facilities regulations
-
Re § 29 Passive fire protectionPassive fire protection 29 For determination of fire loads according to the first subsection, see Section 11. Adequate fire resistance as mentioned in the first subsection, should be determined in relation
- Guideline
- The facilities regulations
-
Re § 31 Fire divisionsFire divisions 31 Fire divisions with coated or sprayed-on fire protection material that does not fulfil the requirements for incombustibility, can be used if an overall assessment indicates that this
- Guideline
- Technical and operational regulations
-
§ 31 Fire divisionsFire divisions 31 The main areas of onshore facilities shall be separated so that they can withstand the design fire and explosion loads. Rooms and other defined areas with important functions and important
- Paragraph
- Technical and operational regulations
-
§ 29 Passive fire protectionPassive fire protection 29 Where passive fire protection is used, this shall be designed such that it provides relevant structures and equipment with sufficient fire resistance as regards load capacity
- Paragraph
- The facilities regulations
-
Re § 30 Passive fire protectionPassive fire protection 30 As regards stipulation of fire loads as mentioned in the first subsection, see Section 6, litera a. To determine fire resistance, the test methods in the standards ISO 834
- Guideline
- Technical and operational regulations
-
Statoil - Co-location of office facilities on Melkøya for Hammerfest LNG.Published:for Hammerfest LNG. Statoil - Co-location of office facilities on Melkøya for Hammerfest LNG. Statoil has received consent for the co-location of office facilities on Melkøya for Hammerfest LNG. Statoil
- Consent
- Operations, maintenance, modifications
-
Order to Equinor after investigation of incident involving fall from scaffoldingPublished:Equinor – Hammerfest LNG – investigation of incident involving fall from scaffolding Order to Equinor after investigation of incident involving fall from scaffolding The Norwegian Ocean Industry Authority
- Investigation report
- Scaffolding
- Working environment
- Melkøya
- Equinor
-
Order to Equinor – Hammerfest LNG – ensure and document prudence of activities before resumption of workPublished:Order to Equinor – Hammerfest LNG – ensure and document prudence of activities before resumption of work The Norwegian Ocean Industry Authority (Havtil) has issued an order to Equinor to ensure and document
- News
-
Equinor – Hammerfest LNG – safety systems and the company's follow-up of SIL in operationsPublished:Equinor – Hammerfest LNG – safety systems and the company's follow-up of SIL in operations Equinor – Hammerfest LNG – safety systems and the company's follow-up of SIL in operations The Norwegian Ocean
- Audit report
- Process safety
- Equinor
- Melkøya
-
Order to Equinor – Hammerfest LNG – materials handling and work at heightPublished:Equinor – Hammerfest LNG – materials handling and work at height Order to Equinor – Hammerfest LNG – materials handling and work at height The Norwegian Ocean Industry Authority (Havtil) has carried out
- Audit report
- Handling, cranes and lifting
- Equinor
- Melkøya
-
Statoil - Hammerfest LNG - Control systems and surface maintenance – corrosion under insulationPublished:Statoil - Hammerfest LNG - Control systems and surface maintenance – corrosion under insulation Statoil - Hammerfest LNG - Control systems and surface maintenance – corrosion under insulation On 1 and
- Audit report
- Maintenance management
- Statoil
- Melkøya