§ 73 Establishment of emergency preparedness
The operator or the party responsible for operating a facility shall prepare a strategy for emergency preparedness against hazard and accident situations, cf. also the Management Regulations Section 9 litera c. The emergency preparedness shall be established, inter alia, on the basis of results from risk and emergency preparedness analyses as mentioned in Section 17 of the Management Regulations and the defined hazard and accident situations and barrier performance requirements, cf. Section 5 of the Management Regulations. For the establishment of emergency preparedness with dispersants and beach-cleaning agents, refer to Chapter 19 of the Pollution Control Regulations (in Norwegian only).
The emergency preparedness against acute pollution shall cover the ocean, coast and shoreline. The operator shall have three independent barriers, cf. Section 5 of the Management Regulations, one near the source, one in fjord and coastal waters and one at shoreline. The barrier near the source and in the open sea shall be able to handle the quantity of pollution that can fall to the barrier. Barriers in fjord and coastal waters and at shoreline shall be able to handle the quantity of pollution that can fall to the barrier after the effect of the previous barrier has been taken into account.
Where the emergency preparedness is related to activities as mentioned in Section 25 of the Management Regulations, Section 26 of the Management Regulations applies.
The Norwegian Environmental Agency can make further demands on the extent of emergency preparedness against acute pollution.
Section last changed: