Objective

The objective of the audit was to verify that OKEA’s management of materials handling and work at height complied with the company’s own and the authorities’ requirements, so as to reduce the likelihood of failures.

Result

Four non-conformities were identified concerning:

  • Deficient follow-up of scaffold management systems
  • Hose station on north side
  • Role of technical responsible person
  • Training and exercises – emergency operation of lifting facilities

In addition, two improvement points were identified concerning:

  • Fall rescue
  • Competence

What happens next?

We have asked OKEA to report to us by 2 September 2025 on how the non-conformities will be addressed, and to give us their assessment of the improvement points observed.