Objective

The objective of the audit was to verify that Equinor is securing structural safety in compliance with the regulatory requirements.

Result

We identified no non-conformities or improvement points.

In this audit, we also asked the company to identify its own findings. By asking them about their own views of actual conditions, we are able to obtain a picture of their own perception of the realities.

Equinor identified improvement points linked to:

  • Governing documents
  • Competence
  • Maintenance

The objective of this type of self-evaluation is to gain an insight into the operator’s perception of the realities, what this is based on and how the company assesses and addresses these realities.

We have asked Equinor to report on how the improvement points will be addressed.