§ 3 Definitionsfacility with living quarters. Fire area: An area that is separated from other areas by a fire/explosion division or adequate distance, such that the design load for a fire or explosion does not lead to
- Paragraph
- The facilities regulations
-
Re § 29 Hazardous materials and explosivesHazardous materials and explosives 29 To assess and select measures to prevent or reduce the risk of fire and explosion, relevant parts of ISO 13702 (Chapter 8, Annexes A and B, Table C2) and EN 1127-1 should
- Guideline
- Technical and operational regulations
-
§ 12 MaterialsSection 11, manufacturing, joining and construction processes, possible use of materials protection, fire resistance properties, effect of added chemicals, individually and in combination, on the material
- Paragraph
- The facilities regulations
-
Re § 35 Gas release systemthe following additions: Rapid depressurisation should be selected rather than passive fire protection. For fire loads, reference is made to Section 11, When designing gas release systems, external environment
- Guideline
- The facilities regulations
-
§ 11 Loads, load effects and resistancedimensioning accidental load. When determining design loads, the effects of fire water shall not be considered. This applies to both fire loads and explosive loads. Installations, systems and equipment that are
- Paragraph
- The facilities regulations
-
Re § 12 Materialsmaterials as regards fire-resistance characteristics as mentioned in litera d, non-flammable materials should be chosen. Where flammable materials are used, they should limit the spread of fire and produce little
- Guideline
- The facilities regulations
-
Re § 14 Pipeline systemswith the following addition: The pipeline system should be laid and designed such that the risk of fire, explosion and other unintended incidents is minimised, and such that the surroundings are affected
- Guideline
- Technical and operational regulations
-
Re § 43 Emergency preparedness vesselsloading and unloading of recovered oil, operation in areas where there is a risk of explosion and fire. Aircraft that are to be used in actions against acute pollution, should be designed so that they
- Guideline
- The facilities regulations
-
Re § 7 Main safety functionssafety functions as mentioned in literas a and e, applies for the time until the areas outside of the fire area where the accident occurs have been evacuated, including the time it takes to carry out the search
- Guideline
- The facilities regulations
-
Re § 20 Chemicals and chemical exposurecomponents. For use of chemicals, see Section 48 of these regulations. For design and placement as regards fire and explosion hazard as mentioned in the second subsection, litera c, reference is made to Section
- Guideline
- Technical and operational regulations
-
1990s: Shifting to the seabedPublished:multiphase flow technology, gas and condensate can be piped 143 kilometres from this field to the Hammerfest LNG plant on the north Norwegian coast. Subsea factories Technology developed in the 1990s laid
- Feature
- Structural safety
- Process safety
-
Re § 33 Emergency shutdown systemshould be used. The requirement for independence as mentioned in the first subsection, implies that the fire and gas detection system comes in addition to systems for management and control and other safety
- Guideline
- Technical and operational regulations
-
Re § 35 Depressurisation and flare systemas well as Attachment B.2, and the API Standard 521 should be used, with the following additions: fire protection, when designing depressurisation and flare systems, external environment considerations
- Guideline
- Technical and operational regulations
-
Re § 38 Emergency power and emergency lightingThe emergency lighting should contribute to ensure evacuation, and indicate the location of manual fire-fighting equipment and other safety equipment. The emergency lighting should be connected to the emergency
- Guideline
- Technical and operational regulations
-
§ 10a Ignition source controldo so from a central or strategic location, in accordance with the facility specific strategy for fire and explosion safety. 612-1033-F2025_1-10a
- Paragraph
- Technical and operational regulations
-
Eni Norge - Use of Songa Enabler on the Goliat fieldPublished:field is in production licence 229 in blocks 7122/7 and 7122/10, around 85 kilometres northwest of Hammerfest. Drilling is scheduled to begin in late January 2018. The activity is expected to last for 116
- Consent
- Use of facility
-
Re § 8 Structures and materialsthe NORSOK M-004 standard can be used as a basis. When selecting materials with regard to technical fire qualities as mentioned in litera d, non-flammable materials should be chosen. In those cases where
- Guideline
- Technical and operational regulations
-
Re § 34 Process safety systemssystems 34 The requirement for independence as mentioned in the first subsection, implies that the fire and gas detection system comes in addition to systems for management and control and other safety
- Guideline
- Technical and operational regulations
-
§ 33 Emergency shut-down systemhydrocarbons and chemicals to and from the onshore facility, and which isolate the onshore facility's fire areas. 612-1033-F2025_1-33
- Paragraph
- Technical and operational regulations
-
§ 7 Main safety functionsaccident situation: preventing escalation of accident situations so that personnel outside the immediate fire area are not injured, the capacity of main load-bearing structures until the facility has been evacuated
- Paragraph
- The facilities regulations