Re § 33 Emergency shutdown systemcompartmentalise the fire areas on the facility means, inter alia, that a sufficient number of sectionalising valves shall be installed in the processing facility to ensure that any fire load in the event
- Guideline
- The facilities regulations
-
Re § 3 Definitionsplant tank area pipe trenches flares control rooms manned buildings in general (workshop, laboratory, fire station, administration buildings) unmanned buildings (substations, analyser buildings, warehouses)
- Guideline
- Technical and operational regulations
-
§ 16 Drainage systemshall be equipped with drainage systems that can collect and divert liquids to reduce the risk of fire, harm to personnel and pollution. 612-1033-F2025_1-16
- Paragraph
- Technical and operational regulations
-
Investigation following incident on Statfjord A: Self-ignition of iron sulphidePublished:Investigation following incident on Statfjord A: Self-ignition of iron sulphide On 17th April 2024, a fire occurred in a separator on Statfjord A as a result of iron sulphide being exposed to oxygen. The incident
- News
- Process safety
- Working environment
-
§ 29 Hazardous materials and explosivessubstances and explosives shall be marked, handled and stored so that the risk of and in connection with fire, explosion and other accidents is as small as possible. Hazardous substances and explosives shall
- Paragraph
- Technical and operational regulations
-
Equinor – Åsgard A – technical and operational barriers for pipes, process systems and structural elementsPublished:in compliance with the HSE regulations. Result One non-conformity was identified. This concerned: Fire water supply We also observed four factors that we have chosen to categorise as improvement points
- Inspection report
- Structural safety
- Process safety
- Equinor
- Åsgard A
-
Re § 16 Drainage systemssufficient capacity to drain water that gathers in the installation during precipitation and during fire-fighting, that any oily surface water is cleaned out before discharge, that the collection system
- Guideline
- Technical and operational regulations
-
Eni Norge - Use of Songa Enabler on the Goliat fieldPublished:field is in production licence 229 in blocks 7122/7 and 7122/10, around 85 kilometres northwest of Hammerfest. Drilling is scheduled to begin in late January 2018. The activity is expected to last for 116
- Consent
- Use of facility
-
Re § 36 Firewater supplythe facility's largest fire area plus the largest of the adjacent areas. A pump start-up failure does not need to be used as a basis for capacity calculations for the largest fire area plus the largest
- Guideline
- The facilities regulations
-
Re § 24 Outdoor work areasaccumulation of flammable gases, hazard of increased explosion pressure and potentially reduced access for fire-fighting. With regard to new constructions and modifications, weather protection requirements should
- Guideline
- Technical and operational regulations
-
Equinor – Sture and Kollsnes – electrical facilities and the working environmentPublished:Electrical facilities (Kollsnes) Follow-up of hired electrical personnel (Kollsnes & Sture) Barriers for fire prevention in substations (Kollsnes & Sture) Maintenance of emergency lighting and marking of barrier
- Inspection report
- Working environment
- Electrical installations
- Process safety
- Equinor
- Sture
- Kollsnes
-
§ 3 Definitionsinstallations. Fire area: Area, building or room that is separated from other areas by a fire division, such that the likelihood of spread in the event of a design fire load is reduced. Fire division: Distance
- Paragraph
- Technical and operational regulations
-
Eni - Goliat FPSO - Technical and operational barriersPublished:management Fire-fighting strategy The need for and the role of the "Stop Blowdown" function The cooling water system for the emergency generator unit Ventilation in the cargo pump room Fire water supply
- Inspection report
- Eni Norge
- Goliat FPSO
-
ConocoPhillips - Ekofisk - Corrosion under insulation (CUI)Published:Corrosion under insulation (CUI) From 20 August to 5 September 2018, we carried out an audit of passive fire protection, corrosion under insulation (CUI) including surface treatment and repairs under insulation
- Inspection report
- Process safety
- Structural safety
- ConocoPhillips
- Ekofisk J
-
§ 20 Chemicals and chemical exposurebe considered: health and safety of personnel, corrosion and other forms of material decomposition, fire and explosion hazard, and risk for pollution. 612-1033-F2025_1-20
- Paragraph
- Technical and operational regulations
-
§ 15 Chemicals and chemical exposurebe considered: health and safety of personnel, corrosion and other forms of material decomposition, fire and explosion hazards, risk of pollution. 634-1033-F2025_1-15
- Paragraph
- The facilities regulations
-
§ 8 Structures and materialsSection 6, manufacturing, joining and construction processes, possible use of materials protection, fire resistance attributes, probable changes in operating conditions, the opportunity to reduce future
- Paragraph
- Technical and operational regulations
-
§ 40 Open drainage systemsequipped with open drainage systems that can collect and divert oil and chemicals so that the risk of fire, harm to personnel and pollution is reduced. The installation shall be designed such that any discharge
- Paragraph
- The facilities regulations
-
Re § 29a Storage, handling and use of explosivescompatibility in Section 77. In addition, explosives should be protected against falling loads and fires during storage. 613-1033-V2025_1-29a
- Guideline
- The activities regulations
-
§ 19 Ventilation and indoor climatechange and provide acceptable air quality. The ventilation shall also be designed so that smoke from fires can be controlled, and so that hazardous and combustible gases cannot penetrate closed non-rated areas
- Paragraph
- Technical and operational regulations