What are you looking for?
79 hits in Regulations
Filters
Regulations
Type
Selected filters
-
Re § 30 Fire divisionsFire divisions 30 For fire divisions in living quarters, see Section 31. For determination of fire and explosion loads as mentioned in the first and second subsections, see Section 11. Worst credible
- Guideline
- The facilities regulations
-
§ 30 Passive fire protectionPassive fire protection 30 Where passive fire protection is used, this shall be designed such that it provides relevant structures and equipment with sufficient fire resistance as regards load capacity
- Paragraph
- Technical and operational regulations
-
§ 30 Fire divisionsFire divisions 30 Main areas and fire areas on facilities shall be separated by fire divisions that can withstand the design loads for fire and explosion. If the fire divisions may be exposed to hydrocarbon
- Paragraph
- The facilities regulations
-
Re § 31 Fire divisionsFire divisions 31 Fire divisions with coated or sprayed-on fire protection material that does not fulfil the requirements for incombustibility, can be used if an overall assessment indicates that this
- Guideline
- Technical and operational regulations
-
§ 31 Fire divisionsFire divisions 31 The main areas of onshore facilities shall be separated so that they can withstand the design fire and explosion loads. Rooms and other defined areas with important functions and important
- Paragraph
- Technical and operational regulations
-
§ 29 Passive fire protectionPassive fire protection 29 Where passive fire protection is used, this shall be designed such that it provides relevant structures and equipment with sufficient fire resistance as regards load capacity
- Paragraph
- The facilities regulations
-
Re § 37 Fire-fighting equipment and systems for fire-fightingFire-fighting equipment and systems for fire-fighting 37 To fulfil the requirement for fixed fire-fighting installations as mentioned in the first subsection, Chapter 12 of the NS-EN ISO 13702 standard
- Guideline
- Technical and operational regulations
-
Re § 30 Passive fire protectionPassive fire protection 30 As regards stipulation of fire loads as mentioned in the first subsection, see Section 6, litera a. To determine fire resistance, the test methods in the standards ISO 834
- Guideline
- Technical and operational regulations
-
§ 37 Fire-fighting equipment and systems for fire-fightingFire-fighting equipment and systems for fire-fighting 37 Installation of fixed fire-fighting installations shall be based on a risk assessment. Onshore facilities shall be equipped with sufficient manual
- Paragraph
- Technical and operational regulations
-
Re § 29 Passive fire protectionPassive fire protection 29 For determination of fire loads according to the first subsection, see Section 11. Adequate fire resistance as mentioned in the first subsection, should be determined in relation
- Guideline
- The facilities regulations
-
§ 37 Fixed fire-fighting systemsFixed fire-fighting systems 37 Fixed fire-fighting systems shall be installed in explosion-hazard areas and in areas with a major risk of fire. The systems shall also cover equipment containing significant
- Paragraph
- The facilities regulations
-
Re § 32 Fire and gas detection systemsFire and gas detection systems 32 For design of the system as mentioned in the first subsection, the standards NS-EN ISO 13702 with Appendix B.6 and NORSOK S-001 Chapters 13 and 14 should be used. The
- Guideline
- The facilities regulations
-
Re § 31 Fire divisions in living quartersFire divisions in living quarters 31 If the living quarters are located on a separate facility as mentioned in the first subsection litera c, external surfaces and distance to nearby facilities should
- Guideline
- The facilities regulations
-
Re § 32 Fire and gas detection systemFire and gas detection system 32 As regards the design of the system as mentioned in the first subsection, Chapter 11 of the NS-EN ISO 13702 standard as well as Attachment B.6 should be used. The requirement
- Guideline
- Technical and operational regulations
-
Re § 37 Fixed fire-fighting systemsFixed fire-fighting systems 37 In order to fulfil the requirement for fixed systems as mentioned in the first subsection, the standards NS-EN ISO 13702 Chapter 12 and Appendix B.8 and NORSOK S-001 Chapter
- Guideline
- The facilities regulations
-
§ 32 Fire and gas detection systemFire and gas detection system 32 Onshore facilities shall have a fire and gas detection system that ensures quick and reliable detection of incipient fires, fires and gas leaks. The system shall be able
- Paragraph
- Technical and operational regulations
-
§ 31 Fire divisions in living quartersFire divisions in living quarters 31 The living quarters shall be protected by fire divisions that, as a minimum, satisfy fire rating H-60 for external walls which may be exposed to hydrocarbon fire
- Paragraph
- The facilities regulations
-
§ 32 Fire and gas detection systemFire and gas detection system 32 Facilities shall have a fire and gas detection system that ensures quick and reliable detection of near-fires, fires and gas leaks. The system shall be able to perform
- Paragraph
- The facilities regulations
-
§ 46 Manual fire-fighting and firefighters’ equipmentManual fire-fighting and firefighters’ equipment 46 Facilities shall be equipped with sufficient manual fire-fighting and firefighter equipment to effectively combat incipient fires and prevent escalation
- Paragraph
- The facilities regulations
-
Re § 46 Manual fire-fighting and firefighters’ equipmentManual fire-fighting and firefighters’ equipment 46 In order to fulfil the requirements for manual firefighting and firefighters’ equipment, the standards NS-EN ISO 13702 Appendix B.8.12 and NORSOK S-001
- Guideline
- The facilities regulations